Phone: +420 516 416 942, fax: +420 516 416 963, e-mail:


Czech  Czech version  English  English version 

 
 
 
Ikona Page in Acrobat Reader format (130kB)
CONVERTERS OF Pt100 RESISTANCE,
TRANSMITTER RESISTANCE AND THERMOELECTRIC VOLTAGE
 
PX24, PXN24, PXN230

INPUT/OUTPUT ISOLATED, Pt100 RESISTANCE, TRANSMITTER RESISTANCE AND
THERMOELECTRIC VOLTAGE CONVERTER

Profile:
PX24 PXN24, PX230
Obrázek 01 Obrázek 02

Description:

   - designed for DIN 35 rail mounting
   - input and output are isolated from each other as well as from supply circuits
   - conversion accuracy < 0,3%

      The module has been designed to convert the output of a resistance thermometer, resistance transmitter or thermocouple into a unified outputs (0..10V, 0..20mA, 4..20mA). The resistance sensors may be either two-wire or three-wire connected. The module can handle output voltages of any standard Platinum or Nickel sensors, carrying out their temperature-to-resistance transfer function linearization at a time. Two options of the resistance transmitter circuit connection are available, namely, variable resistance and potentiometer. The converter can also handle any standard thermocouple voltages. It provides the thermocouple cold junction compensation at the place of the converter's input terminals. However, no linearization of the thermocouple voltage vs. temperature response curve is provided. The converter is particularly well-suited for heavy electromagnetic interference environment operation and features input-to-output isolation.

Electrical specifications:
- operating temperature range: -25...+70°C
- supply voltage: 12..30V DC, maximum ripple: 0,5V (as measured across the device terminals), for PX24
  24V DC ± 30% for PXN24
  230V AC ± 10% ( 45 - 65 Hz ) for PXN230
- power input: max. 2VA
- current limit: 30mA±5mA
- maximum output voltage: 27V
- output voltage amplitude: min. 15V (R load = 750W) at 20mA (except PX24)
- voltage output load: max. 10mA
- inputs: Pt100, 1000 to IEC 751, any range from -50 to +600°C
         (TMAX-TMIN) = cca 50...600°C
         Ni100, 500, 1000 preferably for TKR 6180 ppm/K
  variable resistance ranging 50W .. 800W in 3w connection
  variable resistance ranging 1kW .. 10KW 2w connection (terminal 2 not connected)
  potentiometer ranging 50W .. 10kW
  thermocouple E, J, K, T, R, S, B, T without linearization
         arbitrary range (TMAX-TMIN) = cca 50...1600°C
- input connection: two or three-wire / two-wire for a thermocouple
- resistance sensor lead-in wire resistance compensation: < 0,03%/1W (for three-wire connection)
- cold junction temperature compensation: by means of a Pt100 internal sensor fitted at the converter terminals < ±1°C
- linearization method: parabolic curve for Pt and Ni, otherwise no linearization
- output: 0..1V, 0..5V, 0..10V, 0..5mA, 0..20mA, 4-20mA
- accuracy: measurement error: < 0,3%
  linearity error: < 0,1%
  temperature induced error: < 0,02%/°C
- enclosure: casing / terminal board: IP40 / IP10
- dielectric strength: 4000Vr.m.s., 50Hz/1 min
- settling time: 300ms
     
Type tests:
Standard type test:
EMC:
Safety:
to CSN EN 60770-1
to CSN EN 61326-1
assessed acc. to CSN EN 61010-1

Terminal connection:
1, 2, 3 ...........
4,5.................
6,7.................
see application examples
output (5 is +)
24V DC power supply terminals (7 is +), or 230V AC depending on the type
these are not connected in PX24, the converter is powered via its output line
The terminals accept wires with cross sections not exceeding 2,5mm2.
 
Picture 03

Converter dimensions:
 
  Picture 04
 

Ordering instructions:
      The device has a fixed factory setting. The input signal type and range cannot be changed. The output setting is fixed, too. The output type of PX24 cannot be selected, it is fixed to 4..20mA. This information must therefore be included in your purchase order.
      Your purchase order should include: converter type, input signal type and range, output signal type and range, number of pieces. Special requirements must be discussed with us beforehand.
 
Most frequently ordered input ranges:
 
RTD Pt100 -50...+50°C
Pt100 -50...+100°C
Pt00 -20...+60°C
Pt100 0...+50°C
Pt100 0...+100°C
Pt100 0...+200°C
Pt100 0...+250°C
Pt100 0...+300°C
Pt100 0...+400°C
Pt1000 0…+100°C
Pt1000 0…+200°C
Ni1000 0…+100°C
Ni1000 0…+200°C
OV 3w 0...100W
3w 5...105W
2w 0...500W
2w 0...1000W
2w 0...10000W
2w 0...10KW
Tc "J" 0…+200°C
"J" 0...+400°C
"J" 0...+600°C
"J" 0...+800°C
"K" 0...+100°C
"K" 0...+400°C
"K" 0...+600°C
"K" 0...+900°C
"K" 0...+1000°C
"K" 0...+1200°C
"S" 0...+1400°C
"S" 0...+1600°C
 
... other ranges by request
Potentiometer Pot. 0...100W
Pot. 5...105W
Pot. 0...105W
Pot. 0...1KW
Pot. 0...10KW
 
Examples: PX24 Potentiometer 0...1KW, 2 pcs.
PXN24 Pt100 0...+100°C/4..20mA, 1 pc.