PROGRAMMABLE CONVERTER
 
 
PX210

PROGRAMMABLE ISOLATED DIGITAL CONVERTER

Profile:
  PX210
  Obrázek 01

Description:
  - input for DC current, voltage or termocouple
- conversion accuracy < 0.1%
- output signal is standard 4...20 mA.
- input and output are isolated - 4kV
- designed for DIN 35 rail mounting

Electrical specifications:
- operating temperature range: -25...+70°C
- supply voltage: 8...28V DC (polarity reversal protection)
- output resolution: 0,025%
- input signal: termocouple J, T, K, E, N, L, S, R, B,C,D,G
direct voltage by order for instance: 0...1V, 0...10V, 0...300V, max.600V
direct voltage current for instance: 0...20mA, max 2A
- accuracy: conformity error: < 0,1% from range
  temperature effect: <0,05%/10K
- damping 0..30s
- protection housing / terminal: IP40 / IP10
- montage: DIN 35 mm rail
- leads connection: wire 0,5 až 2,5mm2
- custom linearization: yes
- accessory (optional): programmable adaptor PK-USB (with free SW)
- dimension: see schema
     
Type of thermocouple Range Nonlinearity error
Fe-Ko L DIN 43 710 -25 .. +900°C 0,1%
Fe-Ko J EN 60 584 -210 .. +1200°C 0,1%
Cu-Ko T EN 60 584 -270 .. +400°C 0,1%
NiCr-Ni K EN 60 584 -270 .. +1372°C 0,1%
NiCr-Ko E EN 60 584 -270 .. +1000°C 0,1%
NiCrSi-NiSi N EN 60 584 -270 .. +1300°C 0,1% od -130°C
Pt10Rh-Pt S EN 60 584 -50 .. +1760°C 0,15% od 0°C
Pt13Rh-Pt R EN 60 584 -50 .. +1767°C 0,15% od 0°C
Pt30Rh-Pt6Rh B EN 60 584 0 .. +1820°C 0,15% od 400°C
W3Re-W25Re D   0 .. +2495°C 0,15% od 500°C
W5Re-W26Re C   0 .. +2320°C 0,15%
W-W26Re G   0 .. +2315°C 0,15% od 500°C
Type tests:
Basic type test:
EMC:
Safety:
- in compliance with ČSN EN 60770-1
- in compliance with ČSN EN 61326-1
- in compliance with ČSN EN 61010-1

Terminal connection:
4(-), 5(+):
1(-), 3(+):
supply 8...28V DC
input
Obrázek 02

Dimmension schema:
 
Obrázek 03


Ordering:
In an order is necessary notify:
 - type of converter PPL100
 - number of pieces
Ordering:

In an order is necessary notify:
  - type of converter PX210
- number of pieces
- input signal
                thermocouple and it type
                direct voltage
                direct current

Order example:
  PX210; 5 pc; Tc J (0..800°C)/4-20mA
PX210; 2 pc; 0..120 mV/4-20mA
PX210; 3 pc; ±10V/4-20mA